Show simple item record

dc.contributor.authorMason, Andrew
dc.date.accessioned2018-03-25T21:59:08Z
dc.date.available2018-03-25T21:59:08Z
dc.date.issued2014-06
dc.identifier.citationMason, A. (2014). Characterization of grey water in Kyebando, Kisalosalo and determination of the design criteria for greywater systems treating water for irrigation. Unpublished Masters thesis. Makerere University, Kampala, Ugandaen_US
dc.identifier.urihttp://hdl.handle.net/10570/6040
dc.descriptionA thesis submitted in partial fulfillment of the requirements for the award of the Masters of Science Degree in Civil Engineering of Makerere Universityen_US
dc.description.abstractIn many urban and peri-urban communities of low and medium income countries, grey water discharge is of increasing concern as population in these areas continues growing, consequently bringing about an increase in quantities of grey water generated. The main objective of this study was to characterize the grey water in Kyebando, Kisalosalo Zone (Kampala) and design a method of treatment so that it can be upgraded to a safe resource for irrigation Literature review, questionnaires and observations among other methods were used for data collection. Based on our measurements, the amount of grey water generated in Kyebando is on average 65L/household/day. Analysis was carried out on grey water samples from the area of study to establish the current grey water characteristics. The characteristics of grey water in Kyebando are (on average) 483mg/L, 888mg/L, 11mg/L, 35.9mg/L, 7.9mg/L,5845 cfu/100mL 346mg/L, 6.6 and 459μS/cm for BOD5, COD, NH4-N, TP, Ortho P, faecal coliforms, TSS, pH and EC respectively. These parameters suggest that grey water should be treated before using it at household level. To develop a design criterion, a laboratory scale model treatment unit was set up and its performance was evaluated. A hydraulic loading rate (HLR) of 60 L m-2d-1 and an organic loading rate (OLR) of 70 g BOD m-2d-1 were implemented on a multi-media filter of gravel, charcoal, geotextile and mulch (charcoal being the predominant layer) operated as a batched type system, with a 24 hour retention time. The system was operated for four weeks, during which it showed remarkable removal efficiencies of 76% and 73% after 24hours for COD and BOD, respectively and 73.1% for feacal coliforms (FC). The removal efficiencies at 24 hours, of feacal Coliforms (FC), Total Phosphorous (Tot-P), and Total Suspended Solids (TSS) were 73.3%, 59.5% and 73.7% respectively. A filter system with a surface area of 0.76m2 was recommended for the adequate treatment of household grey water. It treated water to meet the required standards for Irrigation.en_US
dc.description.sponsorshipNational Water and Sewerage Corporationen_US
dc.language.isoenen_US
dc.publisherMakerere Universityen_US
dc.subjectGrey wateren_US
dc.subjectGrey water systemsen_US
dc.subjectIrrigationen_US
dc.subjectWater treatmenten_US
dc.subjectWater pHen_US
dc.subjectSanitationen_US
dc.subjectWater, social economic conditionsen_US
dc.subjectUrna areasen_US
dc.titleCharacterization of grey water in Kyebando, Kisalosalo and determination of the design criteria for greywater systems treating water for irrigationen_US
dc.typeThesis/Dissertation (Masters)en_US


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record